Stall size and aisle width decide how many cars fit on a lot and how easily they move through it. There is no single national standard for regular stalls. Your city or county zoning code sets the minimums, and they differ from place to place. Here are typical numbers from real codes, how the parking angle changes the layout, and where accessible stalls and fire lanes fit in.

Zoning sets the minimums

Regular stall sizes come from local zoning, not federal law. Two examples show how much they can differ. Olive Branch, Mississippi requires 90 degree stalls 9 feet wide and 20 feet deep with a 25 foot aisle. Henrico County, Virginia requires 9 by 18 foot stalls with a 24 foot two-way aisle and an 18 foot one-way aisle. Same kind of lot, different rules.

Before you change a layout, call the planning or zoning office for the city or county and ask for the current parking standards. If the lot was built from an approved site plan, start there. Olive Branch, for one, requires parking spaces to be shown on the site plan with the intended striping and numbered.

Drone view of a full retail lot striped stall to stall
Drone view of a full retail lot striped stall to stall.

90 degree parking

Straight-in stalls on both sides of a two-way aisle are a common layout for shopping centers, schools and office lots. In the Olive Branch table, 90 degrees is the only stall angle paired with an aisle that is not limited to one-way traffic. That ordinance also lets the 90 degree stall depth be reduced where curbs or wheel stops are used and the car's overhang does not run into landscaping.

90°9 FT × 20 FT STALL25 FT AISLE60°9 FT WIDE, 20 FT DEEP18 FT 6 IN ONE-WAY45°20 FT 6 IN DEEP13 FT 6 IN ONE-WAYExample minimums from the Olive Branch, MS zoning table cited in the guide. Your town sets its own numbers.
Stall angle and aisle width examples from a Mississippi zoning table: 90, 60 and 45 degree parking (not to scale).

Angled parking and one-way aisles

Angled stalls let drivers pull in with less turning, but they point traffic in one direction. In Olive Branch, 60 degree stalls are 9 feet wide and 20 feet deep with an 18 foot 6 inch aisle. 45 degree stalls are 20 feet 6 inches deep with a 13 foot 6 inch aisle. 30 degree stalls are 20 feet deep with a 13 foot aisle. Every one of those aisles is one-way only.

Henrico County goes the other way around: when a one-way aisle is proposed, parking must be at 60 degrees. Either way, angled layouts depend on drivers knowing which way to go, so the directional arrows in the aisle and at the ends of each row matter as much as the stall lines.

Parallel parking

Parallel spaces are longer and narrower. Olive Branch sets them at 8 feet wide with 23 feet of curb length and a 12 foot one-way aisle. Where parallel parking sits next to angled parking, the aisle must be at least as wide as the largest adjacent angle aisle. Henrico County sets parallel stalls at 8 by 22 feet. Parallel spaces show up along building fronts, service drives and narrow side lots.

Yellow stall lines restriped on an older concrete lot
Yellow stall lines restriped on an older concrete lot.
Curving apartment lot with fresh white stalls and accessible spaces
Curving apartment lot with fresh white stalls and accessible spaces.

Fitting in accessible stalls

Accessible stalls follow the 2010 ADA Standards, not just local zoning. A car space is at least 96 inches wide with a 60 inch access aisle that is at least as long as the space. A van space is either 132 inches wide with a 60 inch aisle, or 96 inches wide with a 96 inch aisle. Two spaces can share an aisle, except angled ones.

Under ADA guidance, stall width is measured to the centerline of the markings, and the end space may include the full line width. Access aisles cannot overlap a drive aisle. Accessible stalls go on the shortest accessible route to an accessible entrance, so plan them first and fit regular stalls around them.

ISAISASTANDARD96 IN MIN60 IN AISLE132 IN VAN60 IN AISLECAR SPACE + AISLE · VAN SPACE + AISLE (OPTION 1)Aisle at least as long as the space and level with it. Space and aisle slope no more than 1:48 (about 2%).Van option 2: a 96 in space with a 96 in aisle. Sign mounted 60 in min to the bottom. Source: 2010 ADA Standards.
Accessible car and van spaces with striped access aisles, per the 2010 ADA Standards (not to scale).

Drive aisles, fire lanes and surface

Some drive aisles double as fire lanes. The International Fire Code calls for fire apparatus access roads to have at least 20 feet of unobstructed width and 13 feet 6 inches of clearance, and they cannot be obstructed by parked vehicles. If the local fire code official has designated a lane along your building, stalls cannot creep into it.

Surface and drainage matter too. Olive Branch requires parking areas to have a Portland cement or asphaltic concrete surface maintained for all-weather use, drained so water does not flow across sidewalks. It also requires parking for non-residential uses and for multifamily buildings of three or more units to be marked with striping.

Apartment parking with accessible stalls marked in blue, from above
Apartment parking with accessible stalls marked in blue, from above.

How we approach a layout

Straight Line Services does new traffic layout and design along with striping, across Mississippi, Louisiana, Tennessee, Alabama and Arkansas. We work from your site plan and your local code, figure the accessible stall count, mark the layout on the pavement, and walk it with you before paint goes down. Call or text 662-719-7737 for a free estimate.

Need this done? Straight Line Services gives free estimates from Ruleville. Call or text 662-719-7737.

Free estimate

From our jobs

The work behind this guide

Photos from Straight Line Services jobs.

See all recent work
New white stall lines on a fresh asphalt lot
New white stall lines on a fresh asphalt lot
Night drone view of blue accessible stalls by a building
Night drone view of blue accessible stalls by a building
Drone view of a small concrete lot with fresh yellow stalls
Drone view of a small concrete lot with fresh yellow stalls
Accessible stalls, crosswalk and stalls at a retail entrance, from above
Accessible stalls, crosswalk and stalls at a retail entrance, from above
Yellow arrow painted at a driveway entrance
Yellow arrow painted at a driveway entrance
Dusk drone view of stalls and crosshatched no-parking areas at a store
Dusk drone view of stalls and crosshatched no-parking areas at a store
Yellow lines and blue accessible stalls on concrete by a brick building
Yellow lines and blue accessible stalls on concrete by a brick building
New yellow stall lines on an older concrete lot
New yellow stall lines on an older concrete lot
Yellow crosshatched no-parking area and stalls by a building
Yellow crosshatched no-parking area and stalls by a building
Fresh stalls and blue accessible aisles along a new building at dusk
Fresh stalls and blue accessible aisles along a new building at dusk

Questions

Common questions

What is the standard parking space size?

There is no single national size for regular stalls. Codes we checked use 9 feet wide, with depths of 18 feet in Henrico County, Virginia and 20 feet in Olive Branch, Mississippi. Your local zoning code sets the minimum, so check with the planning office.

How wide should a two-way drive aisle be?

It depends on local code. Henrico County requires 24 feet for two-way aisles. Olive Branch requires 25 feet next to 90 degree parking. If the aisle is also a fire lane, the fire code calls for at least 20 feet of unobstructed width.

Can I fit more cars by making stalls narrower?

Only down to your zoning minimum, and only if accessible stalls, aisles and any fire lanes still meet their rules. Reconfiguring a lot also means accessible spaces must be provided under ADA guidance. Check with the city or county before you change anything.

Do angled stalls need one-way aisles?

In the codes we checked, yes. Olive Branch limits aisles serving 30, 45 and 60 degree stalls to one-way traffic, and Henrico County requires 60 degree parking when a one-way aisle is proposed. Clear arrows keep drivers going the right way.

Free estimates

Tell us about the job

Land or lot, one number reaches both companies. Call, text or send a few details. Only your name and phone are needed.

  • Only your name and phone are required
  • Land clearing, dirt work and demo across the Delta
  • Parking lot striping in MS, LA, TN, AL and AR
  • Rather talk now? Call or text 662-719-7737

Free estimates

Tell us about the job

Only your name and phone are needed. We call you back.

CallFree estimate